
Facility Executive Technical
- 🇮🇳 India
- On-site
- Manager or above
- 1 day ago
- SPC
- LOTO
- HVAC
- Airflow
- VFDs
- calibration
- Windows
- ASHRAE
- NFPA
- IEC
- AI
JLL empowers you to shape a brighter way. Â
Our people at JLL are shaping the future of real estate for a better world by combining world class services, advisory and technology for our clients. We are committed to hiring the best, most talented people and empowering them to thrive, grow meaningful careers and to find a place where they belong. Whether you’ve got deep experience in commercial real estate, skilled trades or technology, or you’re looking to apply your relevant experience to a new industry, join our team as we help shape a brighter way forward. Â
Facility Engineer with below requirement.
A. Power Quality, Distribution & Reliability
- Operate and maintainLT systems, transformers, LT panels, PDU/RPP, isolation transformers, andstatic transfer switches (STS).
- EnsureN+1 / 2N redundancy for critical loads (process tools, scrubbers, abatement, BMS, safety systems).
- Monitorharmonics (THD), transients, flicker, andEMI/RFI; implementfilters/SPDs and isolation strategies for sensitive tools (litho, metrology).
- Performload studies, phase balancing, and feeder capacity checks prior totool hookups and expansions.
B. UPS, Emergency Power & Controls
- Operate and maintainUPS (modular/N+1), battery strings, DG sets, AMF/ATS panels; testblack start andautotransfer sequences.
- Periodicbattery health tests (IR, discharge tests), UPS efficiency tuning, and firmware/config backup.
- MaintainEmergency Power Off (EPO) circuits, interlocks with gas monitoring systems, andfire alarm interfaces.
C. Grounding, Bonding & ESD
- Maintainclean/technical grounds, separate from building ground; verifylow-impedance paths and equipotential bonding for tools.
- Implement and auditESD controls (SEMI S20.20 practices), wrist straps, surfaces, flooring resistance, and static-safe layouts in cleanroom and chase areas.
D. Maintenance, Monitoring & Response
- EstablishPM/CBM for panels, breakers, relays, STS, UPS, andIR thermography for hot spots.
- TrendMTBF/MTTR, createSPC charts for voltage, frequency, THD, and temperature rise.
- LeadRCA on trips/nuisance faults; implement corrective and preventive actions.
E. Safety & Compliance (Electrical)
- EnforceLOTO, arc-flash boundaries, insulated tools, and PPE.
- Maintainsingle-line diagrams, relay settings,test reports (IR, ER), and statutory compliance underCEA Regulations, IndianElectrical Safety Rules, and local inspectorate requirements.
- IntegrateBMS/EPMS alarms, define SOPs for emergency shutdowns and controlled restarts.
2) Facility Engineer –Mechanical / Process Utilities (Semiconductor Labs)
Primary Objective:
Ensurestable, spec-compliant utilities for process tools and cleanroom performance with high uptime and contamination control.
A. Cleanroom & HVAC (Critical Environment)
- Operate and optimizeMAUs/AHUs/FFUs,HEPA/ULPA filtration,pressurization cascades, temperature & RH controls.
- MaintainISO 14644 cleanroom classes; trackparticle counts, airflow, androom recovery times.
- Handlefilter life-cycle management, leak tests (DOP/PAO),duct hygiene, andIAQ.
- Seasonal tuning of coils,economizer modes, anddew point management to prevent condensation in bays/chasers.
B. Chilled Water / PCW /
- Operatechillers (centrifugal/screw), CTs, primary/secondary pumping, andPCW loops for tools.
- Maintaintemperature stability, ΔT, flow, andvibration on critical pumps; maintainN+1 for critical circuits.
- Water treatment: scaling/corrosion inhibitors,biocide control, blowdown optimization.
- Trending:SPC on supply temp, differential pressure,specific energy consumption.
C. Ultra-Pure Water (UPW/DI) & Wastewater
- Managerinse loops, sanitization schedules, andreturn/reclaim strategies (if applicable).
D. Compressed Air (CDA), Vacuum & Inert Gases
- Operateoil-free compressors, dryers, and filtration to meetdew point and oil/particulate specs; maintainVMB/VMP pressures.
- Maintaincentral vacuum anddry pump systems for tools; planoverhauls,flushing, andpump swap programs with OEMs
- Manage bulk/packagednitrogen (Nâ‚‚), vacuum-jacketed lines (if LNâ‚‚), and purges for tools and abatement.
E. Fire, Life Safety & Exhaust/Ventilation
- Maintainprocess exhaust,toxic exhaust, andgeneral exhaust with redundancy and failure interlocks.
- Coordinate withfire detection/suppression (VESDA, clean agent where applicable), and ensureSEMI S2/S6/S8/S18 oriented risk controls.
F. Maintenance, Monitoring & Analytics PPM
- CreatePM schedules for pumps, compressors, chillers, FFUs, filters, cabinets, scrubbers, UPW, and neutralization systems.
- UseBMS to alarm, trend, and report; deploypredictive maintenance (vibration, oil analysis, dew point trends).
- Maintainspares strategy for high-risk items (VFDs, AHU motors, pump seals, pH probes, sensors, HEPA/ULPA, MERV prefilters).
H. Safety & Compliance (Mechanical/Utilities)
- EnforcePTW/LOTO, confined space, hot work, and chemical handling SOPs.
- Comply withFactory Act,Boiler Regulations (if applicable),Lift Act, localPCB norms for discharge,PESO/SMPV Rules for gas storage, andexplosion-proof ratings where needed.
- MaintainMSDS/SDS, calibration certificates, andinterlock validation records.
3) Common Responsibilities (Both Electrical & Mechanical)
Projects & Tool Hookups
- ReviewPFD/P&ID,MEP/shop drawings, andhook-up packages; validate utility points, capacity, and interlocks.
- CoordinateFAT/SAT, commissioning, andas-built updates; manage change control and redlining.
- Planshutdowns with clearMOPs (Method of Procedure) and rollback plans—particularly when tying into live loops.
Operations, Documentation & Reporting
- MaintainO&M logs,trend charts,equipment history, andSOP/EOP libraries.
- GenerateMIS: uptime, incidents, energy use, water use, chemical use, andenvironmental KPIs (e.g., CUE/WUE).
- TrackOEE,MTBF/MTTR, andSPC metrics for critical utilities and cleanroom performance.
Vendor/OEM & AMC Management
- Manage AMCs forchillers, compressors, scrubbers, UPS, gas detection, andUPW.
- Validateservice reports,calibration certificates, andPM checklists; enforce spares and response SLAs.
- ConductRCA with OEMs for chronic faults and implement design/controls improvements.
EHS, Training & Culture
- Runtoolbox talks, competency training (LOTO, toxic gas, electrical safety, ESD, cleanroom behavior).
- LeadHIRA/JSA, safety walks, andnear-miss programs; maintainpermit-to-work rigor.
- Interface withQA/EHS/Process teams to align operational windows with experiment schedules and risk profiles.
4) Day/Week/MonthChecklist Snapshot
Daily
- Power quality & alarms (EPMS/BMS): voltages, THD, breaker statuses, UPS load, battery float.
- Cleanroom:pressures, temp/RH, particle counts (critical bays), FFU/AHU alarms.
- Utilities:CDA dew point & oil carryover, PCW temps/flows, vacuum levels, UPW resistivity/TOC, scrubber DP/pH/ORP.
- Gas monitoring:sensor health, bump tests where applicable; verifyEPO/gas shutdown panels healthy.
Weekly
- Visual checks:hot spots via IR (rotational basis), pump vibrations, belt/tension, filter DP trends.
- Testgenerator no-load/loaded (per schedule), UPS self-tests, reviewalarm logs & interlock events.
- Sample & trendUPW bacteria, cooling tower chemistry; verifytool hook-up backflow preventers.
Monthly
- Full PMs as per OEM: compressor dryers, scrubber spray nozzles,HVAC coils & filters, UPS battery IR.
- Calibration rotation: gas sensors, pressure/flow/temp transmitters, pH/ORP meters.
- Emergency drill (gas leak/EPO) andRCA review of any incidents; update SOPs/MOPs/EOPs.
5) Useful Standards/Frameworks to Align With
- SEMI: S2 (EH&S for equipment), S6 (exhaust ventilation), S8 (ergonomics), S18 (risk assessment), S20/S20.20 (ESD).
- ISO 14644 (cleanrooms),ASHRAE (HVAC),NFPA (fire protection, electrical safety),IEC/IEEE (electrical),FM Global guidance.
- India statutory:CEA Regulations,Factory Act,PESO/SMPV Rules, localPCB andElectrical Inspectorate requirements.
6) Optional Add‑Ons I Can Prepare for You
- JD template for Facility Engineer (Semiconductor Utilities) – ready to publish.
- SOP/MOP/EOP pack for: tool hook-up, toxic gas alarm response, EPO/power restoration, abatement startup, and scrubber failure.
- PM matrix (Daily/Weekly/Monthly/Quarterly/Annual) with OEM references.
- Commissioning & handover checklist (FAT/SAT, interlock validation, redlines).
Educational Qualifications
â—Ź Diploma in Electrical Engineering
â—Ź B.Tech Or BE in Electrical Engineering
Location:
On-site –Bengaluru, KAScheduled Weekly Hours:
48If this job description resonates with you, we encourage you to apply even if you don’t meet all of the requirements. We’re interested in getting to know you and what you bring to the table!
At JLL, we harness the power of artificial intelligence (AI) to efficiently accelerate meaningful connections between candidates and opportunities. Using AI capabilities, we analyze your application for relevant skills, experiences, and qualifications to generate valuable insights about how your unique profile aligns with the specific requirements of the role you're pursuing.
JLL Privacy Notice
Jones Lang LaSalle (JLL), together with its subsidiaries and affiliates, is a leading global provider of real estate and investment management services. We take our responsibility to protect the personal information provided to us seriously. Generally the personal information we collect from you are for the purposes of processing in connection with JLL’s recruitment process. We endeavour to keep your personal information secure with appropriate level of security and keep for as long as we need it for legitimate business or legal reasons. We will then delete it safely and securely.
For more information about how JLL processes your personal data, please view ourCandidate Privacy Statement.
For additional details please see our career site pages for each country.
Jones Lang LaSalle (“JLL”) is an Equal Opportunity Employer and is committed to working with and providing reasonable accommodations to individuals with disabilities. If you need a reasonable accommodation because of a disability for any part of the employment process – including the online application and/or overall selection process – you may email us atHRSCLeaves@jll.com. This email is only to request an accommodation. Please direct any other general recruiting inquiries to ourContact Us page > I want to work for JLL.
Facility Executive Technical · SAU-JLL Saudi Arabia